Section R901 General R901.1 Scope The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. Thermoplastic single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Asphalt shingles shall meet the classification requirements of Table R905.2.4.1 for the appropriate ultimate design wind speed. For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table R905.2.8.2. Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. For SI: 1 inch = 25.4 mm, 1 mile per hour = 0.447 m/s. In areas where the average daily temperature in January is 25F (-4C) or less, Wood shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. SECTION R802 WOOD ROOF FRAMING. Install a nominal 4-inch-wide roof deck flashing tape over all roof sheathing panel seams and cover with #30 felt or equivalent synthetic underlayment. The installation of slate shingles shall comply with the provisions of this section. Asphalt shingle packaging shall bear a. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. Asphalt shingles shall be used only on roof. (R803.1) Spaced lumber sheathing for wood shingle and shake roofing shall conform to the requirements of sections R905.7 and R905.8. The installation of mineral-surfaced roll roofing shall comply with this section. SECTION R804 COLD-FORMED STEEL ROOF FRAMING. Cap nail shank shall have a length sufficient to penetrate through the roof sheathing or not less than, The standard calculations contained in ASTM D7158 assume Exposure Category B or C and a. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. In areas where there has been a history of ice forming along the eaves causing a backup of water, as designated in, The use of above-deck thermal insulation shall be permitted provided that such insulation is covered with an. The installation of modified bitumen roofing shall comply with the provisions of this section. Drip edges shall extend not less than. Asphalt shingles shall be used only on roof. Liquid-applied roofing shall comply with ASTM C836, C957, D1227, D3468, D6083, D6694 or D6947. In areas where there has been a history of ice forming along the eaves causing a backup of water, as designated in, The use of above-deck thermal insulation shall be permitted provided such insulation is covered with an. Same as Maximum Ultimate Design Wind Speed, Preservative-treated shakes and shingles of, Fire-retardant-treated shakes and shingles of, Preservative-treated tapersawn shakes of Southern pine treated in accordance with AWPA Standard U1 (Commodity Specification A, Special Requirement 4.6), Forest Products Laboratory of the Texas Forest Services, Preservative-treated tapersawn shakes of Southern Yellow Pine, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Reroofing shall not be required to meet the minimum design, For roofs that provide positive drainage, recovering or replacing an existing, Complete and separate roofing systems, such as standing-seam metal roof systems, that are designed to transmit the roof loads directly to the building's structural system and do not rely on existing roofs and, Where the existing roof has two or more applications of any type of. The installation of slate shingles shall comply with the provisions of this section.
2018 irc roof sheathing requirements - kazuyasu.net 12 oz/sq ft for preformed metal shingle systems. Adjacent segments of drip edge shall be overlapped not less than 2 inches (51 mm).
PDF Esr-3012 - Westlake Royal Roofing Llc A liquid-applied protective coating that complies with Table R905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. Sections of flashing shall have an end lap of not less than 4 inches (102 mm). Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Section R803 Roof Sheathing R803.2 Wood Structural Panel Sheathing (Roof Online Note: This subsection covers plywood and OSB sheathing. Slate shingles shall be secured to the roof with two fasteners per slate. 2. R905.2.1 Sheathing requirements. 2018 IRC Simplified Wall Bracing Provisions 4 Objectives Upon completion, participants will be better able to: 1. For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table R905.2.8.2. Sprayed polyurethane foam roofs shall have a design. Modified bitumen roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Roof valley flashing shall be not less than No. endstream
endobj
startxref
Stainless steel fasteners are acceptable for metal roofs. For open valleys (valley lining exposed) lined with metal, the valley lining shall be not less than 24 inches (610 mm) wide and of any of the corrosion-resistant metals in Table 905.2.8.2. Mineral-surfaced roll roofing shall not be applied on roof. The installation of thermoset single-ply roofing shall comply with the provisions of this section. The International Residential Code (IRC) and the Residential Edition of the Florida Building Code (FBC) both refer to Table R503.2.1.1(1) of the APA Engineered Wood Construction Guide for specs. Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. The bottom layer shall be 18 inches (457 mm) and the top layer not less than 36 inches (914 mm) wide. Mineral-surfaced roll roofing shall conform to ASTM D3909 or ASTM D6380, Class M. Mineral-surfaced roll roofing shall be installed in accordance with this chapter and the manufacturer's instructions. Liquid-applied roofing shall have a design. Fasteners for asphalt shingles shall be galvanized steel, stainless steel, aluminum or copper roofing nails, minimum 12-gage [0.105 inch (3 mm)] shank with a minimum -inch-diameter (9.5 mm) head, complying with ASTM F1667, of a length to penetrate through the roofing materials and not less than inch (19.1 mm) into the roof sheathing. Asphalt shingles shall comply with ASTM D3462. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. For SI: 1 ounce per square foot = 0.305 kg/m, The installation of modified bitumen roofing shall comply with the provisions of this section and the manufacturer's, Modified bitumen roofing shall have a design. hb```g``:AX,;nkga3l~/ * The installation of sprayed polyurethane foam roofing shall comply with the provisions of this section. Install 7/16 in.-structural sheathing (OSB or plywood) on the vertical face of the gable end wall. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Foamed-in-place roof insulation shall be installed in accordance with this chapter and the manufacturer's instructions. Flashing for asphalt shingles shall comply with this section and the asphalt shingle manufacturer's, Base and cap flashing shall be installed in accordance with manufacturer's instructions. Mineral-surfaced roll roofing shall not be applied on roof. For open valleys, valley lining of two plies of mineral-surfaced roll roofing, complying with ASTM D 3909 or ASTM D 6380 Class M, shall be permitted. Asphalt shingles shall meet the classification requirements of Table 905.2.4.1 for the appropriate ultimate design wind speed. over the entire roof and over the 4-inchwide (102 mm) membrane strips and. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with, Flashing against a vertical front wall, as well as soil, A drip edge shall be provided at eaves and rake edges of. Modified bitumen roofing shall comply with the standards in Table R905.11.2.
2018 International Residential Code (Irc) | Icc Digital Codes The installation of slate shingles shall comply with the provisions of this section. %PDF-1.6
%
Interlayment shall comply with ASTM D226, Type I. Chapter 9 also provides requirements for roof drainage, flashing, above-deck thermal insulation, rooftop-mounted photovoltaic systems and recovering or replacing an existing roof covering. Asphalt shingles shall be used only on roof. 26 gage [0.019 inches (0.5 mm)] corrosion-resistant sheet metal and shall extend 10 inches (254 mm) from the centerline each way for roofs having, Each bundle of shingles shall be identified by a. Asphalt shingles shall be fastened to solidly sheathed decks. The lecture and activity format allows participants to discuss the changes, reasons for the changes, and answer knowledge review questions. Self-adhering polymer-modified bitumen. The 2018 IRC specifies the ratios based on climate zone. Drip edges shall extend not less than. The installation of wood shakes shall comply with the provisions of this section. Where anchored masonry veneer is provided on the vertical sidewall, the base flashing shall be provided in accordance with this section and counterflashing shall be provided in accordance with, Flashing against a vertical front wall, as well as soil, A drip edge shall be provided at eaves and rake edges of shingle roofs. The installation of thermoset single-ply roofing shall comply with the provisions of this section. The installation of liquid-applied roofing shall comply with the provisions of this section. Asphalt shingles shall be used only on roof slopes of two units vertical in 12 units horizontal (2:12) or greater. 26 gage [0.019 inch (0.5 mm)] corrosion-resistant sheet metal and shall extend not less than 11 inches (279 mm) from the centerline each way. Paint systems in accordance with ASTM A755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A792, ASTM A875, ASTM A463, or ASTM A653. IRC Section 301.3 Story Height: The ability is restored to construct a story of a dwelling using 12-foot high bearing walls if the wall studs are engineered for gravity loads, wall bracing amounts are increased, and a roof or celling diaphragm provides support to the studs. Mineral-surfaced roll roofing shall be fastened to solidly sheathed roofs. Same as Maximum Ultimate Design Wind Speed, Preservative-treated shakes and shingles of, Fire-retardant-treated shakes and shingles of, Preservative-treated tapersawn shakes of Southern pine treated in accordance with AWPA Standard U1 (Commodity Specification A, Special Requirement 4.6), Forest Products Laboratory of the Texas Forest Services, Preservative-treated tapersawn shakes of Southern Yellow Pine, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet. Self-adhering polymer modified bitumen. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions.
Lateral Bracing in Gable End Walls | Building America Solution Center 2 RESIDENTIAL ROOFING GUIDE 2018 IRC. Slate shingles shall be fastened to solidly sheathed roofs. ASTM B209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum thickness for pressformed shingles. The bottom layer shall be 18 inches (457 mm) and the top layer not less than 36 inches (914 mm) wide. Wood shakes shall be installed in accordance with this chapter and the, The starter course at the eaves shall be doubled and the bottom layer shall be either 15-inch (381 mm), 18-inch (457 mm) or 24-inch (610 mm) wood shakes or wood shingles. The installation of asphalt shingles shall comply with the provisions of this section. Same as Maximum Ultimate Design Wind Speed, Preservative-treated shakes and shingles of, Fire-retardant-treated shakes and shingles of, Preservative-treated tapersawn shakes of Southern pine treated in accordance with AWPA Standard U1 (Commodity Specification A, Special Requirement 4.6), Forest Products Laboratory of the Texas Forest Services, Preservative-treated tapersawn shakes of Southern Yellow Pine, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet. Each bundle of shakes shall be identified by a, The installation of built-up roofs shall comply with the provisions of this section and the manufacturer's. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions.
The installation of asphalt shingles shall comply with the provisions of this section. In areas where the average daily temperature in January is 25F (-4C) or less, Wood shingles shall be installed in accordance with this chapter and the manufacturer's instructions. Slate shingles shall be installed in accordance with this chapter and the manufacturer's instructions. The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s. The installation of wood shingles shall comply with the provisions of this section. DEWALT Building Code Reference: Based on the 2018 International Residential Code | Books & Magazines, Textbooks, Education & Reference, Dictionaries & Reference | eBay! Roof valley flashing shall be not less than No. Paint systems in accordance with ASTM A 755 shall be applied over steel products with corrosion-resistant coatings complying with ASTM A 792, ASTM A 875, ASTM A 463, or ASTM A 653. Liquid-applied roofing shall comply with ASTM C836, C957, D1227, D3468, D6083, D6694 or D6947. The installation of sprayed polyurethane foam roofing shall comply with the provisions of this section. Base flashing shall be of either corrosion-resistant metal of minimum nominal 0.019-inch (0.5 mm) thickness or mineral-surfaced roll roofing weighing not less than 77 pounds per 100 square feet (4 kg/m. Wood shakes shall comply with the requirements of Table 905.8.5. Part III Building Planning and Construction, Chapter 13 General Mechanical System Requirements, Chapter 14 Heating and Cooling Equipment and Appliances, Chapter 19 Special Appliances, Equipment and Systems, Chapter 22 Special Piping and Storage Systems, Chapter 37 Branch Circuit and Feeder Requirements, Chapter 39 Power and Lighting Distribution, Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits, Appendix A Sizing and Capacities of Gas Piping, Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for Use With Type B Vents, Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems, Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation, Appendix E Manufactured Housing Used as Dwellings, Appendix G Piping Standards for Various Applications, Appendix J Existing Buildings and Structures, Appendix T [RE] Solar-Ready ProvisionsDetached One- And Two-Family Dwellings and Townhouses, The provisions of this chapter shall govern the design, materials, construction and quality of, Roofs shall be covered with materials as set forth in Sections 904 and 905. Asphalt shingles shall be tested in accordance with ASTM D7158. Nails shall be corrosion resistant and not less than 11-gage, Tile shall be applied in accordance with this chapter and the, At the juncture of roof vertical surfaces, flashing and counterflashing shall be provided in accordance with this chapter and the, Roof valley flashing shall be of corrosion-resistant metal of the same material as the. A base sheet that complies with the requirements of Section 1507.11.2 of the. A base sheet that complies with the requirements of. Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, ASTM D6162; D6163; D6164; D6222; D6223; D6298, As an alternative, self-adhering polymer-modified bitumen, As an alternative, a minimum 4-inch-wide (102 mm) strip of self-adhering polymer-modified bitumen membrane complying with ASTM D1970, installed in accordance with the, The cap nail shank shall be not less than 0.083 inch (2.11 mm) for ring shank cap nails and 0.091 inch (2.31 mm) for smooth shank cap nails. Modified bitumen membrane roofs shall have a design. 0
Asphalt shingles shall be tested in accordance with ASTM D7158. The installation of thermoplastic single-ply roofing shall comply with the provisions of this section. Exception: Detached accessory structures not containing conditioned floor area. Wood shingles shall be laid with a side lap not less than 1, Roof flashing shall be not less than No. Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Same as Maximum Ultimate Design Wind Speed, Apply in accordance with the manufacturer's, Asphalt-saturated and asphalt-coated organic felt base sheet, Asphalt-saturated organic felt (perforated), Coal-tar primer used in roofing, dampproofing and waterproofing, ASTM B 370 minimum 16 oz/sq ft and 12 oz/sq ft high-yield copper for metal-sheet, ASTM B 209, 0.024 minimum thickness for roll-formed panels and 0.019-inch minimum, Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, As an alternative, self-adhering polymer-modified bitumen, The standard calculations contained in ASTM D 7158 assume Exposure Category B or C and. arrow_right. A liquid-applied protective coating that complies with Table R905.14.3 shall be applied not less than 2 hours nor more than 72 hours following the application of the foam. Slate shingles shall comply with ASTM C406. arrow_right. 26 gage [0.019 inch (0.5 mm)] corrosion-resistant sheet metal and shall extend not less than 11 inches (279 mm) from the centerline each way.
Chapter 9: Roof Assemblies, 2015 IRC portion of the 2018 CT - UpCodes Roof penetrations shall be flashed and sealed in accordance with this chapter. SECTION R801 GENERAL. Flashing for asphalt shingles shall comply with this section. Materials and methods of application used for recovering or replacing an existing, The structural roof components shall be capable of supporting the, Flashings shall be reconstructed in accordance with, Chapter 9 addresses the design and construction of, R902.2 Fire-Retardant-Treated Shingles and Shakes, R902.3 Building-Integrated Photovoltaic Product, R902.4 Rooftop-Mounted Photovoltaic Panel Systems, R903.4.1 Secondary (Emergency Overflow) Drains or Scuppers, R904.3 Material Specifications and Physical Characteristics, Section R905 Requirements for Roof Coverings, R905.2.4.1 Wind Resistance of Asphalt Shingles, R905.14 Sprayed Polyurethane Foam Roofing, R905.17 Building-Integrated Photovoltaic (BIPV) Roof Panels Applied Directly to the Roof Deck, Section R907 Rooftop-Mounted Photovoltaic Panel Systems, R907.1 Rooftop-Mounted Photovoltaic Panel Systems, Building-integrated photovoltaic products. In areas where there has been a history of ice forming along the eaves causing a backup of water as designated in. For SI: 1 ounce per square foot = 0.305 kg/m. (914 mm). Terne coating of 40 lb per double base box, field painted where applicable in accordance with, 0.027 inch minimum thickness: 99.995% electrolytic high-, ASTM D6162; D6163; D6164; D6222; D6223; D6298, As an alternative, self-adhering polymer-modified bitumen, As an alternative, a minimum 4-inch-wide (102 mm) strip of self-adhering polymer-modified bitumen membrane complying with ASTM D1970, installed in accordance with the, The cap nail shank shall be not less than 0.083 inch (2.11 mm) for ring shank cap nails and 0.091 inch (2.31 mm) for smooth shank cap nails. Base flashing against a vertical sidewall shall be continuous or step flashing and shall be not less than 4 inches (102 mm) in height and 4 inches (102 mm) in width and shall direct water away from the vertical sidewall onto the roof or into the gutter. arrow_right. 1. Asphalt shingle packaging shall bear a. Interpretation #: CEB-2018-10-2005-IRC-R905.2.1 Building or Fire Safety Law Interpreted 675 IAC 14-4.3, the 2005 Indiana Residential Code. Asphalt shingles shall be fastened to solidly sheathed decks. Copper, brass, bronze, copper alloy and 300-series stainless steel fasteners shall be used for copper roofs.
Built-up roofs shall be installed in accordance with this chapter and the manufacturer's instructions. Thermoset single-ply roofs shall be installed in accordance with this chapter and the manufacturer's instructions. 2018 International Building Code (IBC) BASIC Upgrade to Premium CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES First Version: Aug 2017 All Codes I-Codes Legend Information Code Sections My Notes 2018 International Building Code (IBC) PREFACE arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right arrow_right Wood shakes shall comply with the requirements of Table R905.8.5. The installation of liquid-applied roofing shall comply with the provisions of this section. Liquid-applied roofing shall comply with ASTM C836, C957, D1227, D3468, D6083, D6694 or D6947. For SI: 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s.
Unvented Conditioned Attic with Spray Foam Insulation Below Roof - PNNL Chapter 9: Roof Assemblies, Residential Code 2018 of Nevada | UpCodes Water soaked or deteriorating decking must be replaced. 201 0 obj
<>
endobj
Table 1 shows an insulation ratio - the R-value on the top of the roof sheathing compared to the total R-value.